How to install v17.04.27 wiTECH Micropod 2


Chrysler, Jeep, Dodge diagnostic VCI interface wiTECH MicroPod 2 software updated!! here, free download wiTECH software v17.04.27 and get the how-to’s of wiTECH 2 app installation to install Chrysler wiTECH software yourself! Also, a wiTECH MicroPod 2 v17.04.27 user manual of key programming is attached here for you.

 

Part 1: v17.04.27 wiTECH download:

On webpage 

It's wiTECH software crack

No need password for wiTECH MicroPod 2 login

No need wiTECH software license

 

Tested OK by professionals @obdii365

Safe to use with wiTECH MicroPod 2 clone (item no. SP271-C1 only)

 

Operation system of wiTECH 2 download:

Windows 7

 

THE MOST IMPORTANT NOTES:

  1. The date of the computer must be the same as the fact
  2. The computer must not be connected to the Internet
  3. Connect the machine to the MicroPod 2 to open the wiTECH software
  4. The system may ask you to turn off the software and turn it on for registration again. Repeat it for several times. Then you can use it normally

 

 

Part 2: How to install wiTECH MicroPod 2 v17.04.27 software crack:

 

Step 1   install AdobeAIRInstaller.exe

Step 2   install jre-6u45-windows-i586.exe

Step 3   install wiTECH_Install_17.04.27.exe

Step 4   Restart the computer

wiTECH diagnostic tool is ready for use!

 

 

Part 3: How to use wiTech MicroPod II clone for auto key programming

 

Step 1

Plug the MicroPOD II device into the OBD port and connect the USB cable from the device to your laptop. This wakes the BUS on the car.

witech-micropod-2-v17-1

Step 2

Manually enter the VIN of the vehicle. This gives you access to the module list.  Select the RFH (Radio Frequency Hub) module. This is the module where the key is registered.

witech-micropod-2-v17-2

Step 3

Next select “Miscellaneous Functions,” then “Program Ignition Fobix.”  At this point, you are prompted to enter the VIN again, followed by the four-digit PIN Code.

witech-micropod-2-v17-04

Step 4

After the four-digit pin is entered you are prompted to hit continue to “Program Ignition FOBIK.” Once you hit continue you must press the UNLOCK button on the FOBIX within 30 seconds (the FOBIX needs to be located near the center console during this procedure).

witech-micropod-2-v17

Step 5

Programming of the Ignition FOBIX is now successful. The new key key is accepted into the car, and the ignition will now turn on and start the car. At this point, you also have the option to program a second key.

 

Part 3: How to use MicroPOD II clone for auto key programming

 

Step 1

Plug the MicroPOD II device into the OBD port and connect the USB cable from the device to your laptop. This wakes the BUS on the car.

 

Step 2

Manually enter the VIN of the vehicle. This gives you access to the module list.  Select the RFH (Radio Frequency Hub) module. This is the module where the key is registered.

micropod-ii-key-programming-1

Step 3

Next select “Miscellaneous Functions,” then “Program Ignition Fobix.”  At this point, you are prompted to enter the VIN again, followed by the four-digit PIN Code.

micropod-ii-key-programming-2

Step 4

After the four-digit pin is entered you are prompted to hit continue to “Program Ignition FOBIK.” Once you hit continue you must press the UNLOCK button on the FOBIX within 30 seconds (the FOBIX needs to be located near the center console during this procedure).

micropod-ii-key-programming-3

Step 5

Programming of the Ignition FOBIX is now successful. The new key key is accepted into the car, and the ignition will now turn on and start the car. At this point, you also have the option to program a second key.

micropod-ii-key-programming-4

Things to Remember:

  • You must be online to program the key.
  • The PIN Code is only good for one session, which lasts 72 hours. After 72 hours the pin code expires.
  • If you input the wrong code for three-time it locks the BCM and you cannot service the vehicle for 24 hours.
  • The key is one-time programmable. Once married to the vehicle it is locked to the car forever. The key can be erased from the car and put back into the same car, but can’t be switched to another car.
  • The placement of the key during initialization is important. It needs to be placed either behind the shifter or in the center console.


 

wiTech Micropod2 red light flashes microprocessor 1 is unresponsive solution:



Problem:

I was ready to connect the wiTECH2 Micropod 2 interface to diagnose Chrysler 300M, but after i connected the adapter with laptop, the MicroPod2 indicator light flashed and software prompted error message “microprocessor 1 is unresponsive”. What’s the problem?

 

Possible cause:
1.Software is not compatible with hardware/firmware.

We have several wiTECH2 Micropod 2 Chrysler diagnostic scan tools clone (SP271-C,SP271-B,SP271), they are made by different manufacturer. Software cannot be mixed used. i.e SP271-C wiTech software can work with SP271-C Micropod II firmware. Please use the default software CD in package. 

 

2. Incorrect connection 

Please follow the correct steps to connect the micropod2

  1. Connect wiTech Micropod2 to vehicle first
  2. If the red indicator light turn on, then connect wiTech to laptop
  3. Open wiTech software (if software detect newer wiTech version,it will run an upgrade.Wait the upgrade completed. If it does not prompt to update software to newer version, just run software)

If you connect to laptop first (power by USB cable) and run software immediately, software and firmware will automatically synchronous upgrade and that will lead to the firmware failure. MUST CONNCT THE DEVICE TO VEHICLE.

If the red indicator flashes, the firmware is damaged. You have to send it back to repair.


 

wiTech MicroPod2 "wiTech Sundown " Error Solution


Error
"Attention: wiTECH 1.0 Sundown

As previously cummuniocated, wiTech 1.0 will no longer diagnose vehicles that are fully supported in wiTECH 2.0 beginning in July.

Please upgrade your micropod to wiTECH 2.0 so that you will not see any lapse in vehicle coverage.
For information on how to upgrade your micropod to wiTECH 2.0, visit webpage at..."
witech-micro-2-shutdown
Solution:
The error is caused by wrong software version. You have installed witech V17.03.10, this old version is not compatible with Micropod. You should install correct V17.04.27 version in software CD.