VCM2 Ford Firmware Update and Downgrade


Confirmed: Ford VCM II (Item No. SP177) firmware upgrade and downgrade is possible.

 

Procedure:

  1. Remove the rubber sleeve shown below.

Vcm Ii Firmware Upgrade Downgrade 01

 

  1. Connect the USB cable to the VCM2 device and hold the (ReSet) button shown as below.

Vcm Ii Firmware Upgrade Downgrade 02

 

  1. Connect the other end of the USB to a computer with IDS V86 installed, and then release the ReSet button until you hear a beep sound.

Vcm Ii Firmware Upgrade Downgrade 03

 

  1. Run Bosch\VCI Software(Ford-VCM-II)\VCI Manger(Ford-VCM-II).

Vcm Ii Firmware Upgrade Downgrade 04

 

  1. When you see the following image, it means you enter the recovery mode.

Vcm Ii Firmware Upgrade Downgrade 05

 

  1. After clicking on the “Recover” button, the program will switch to the VCMII Update interface.

Vcm Ii Firmware Upgrade Downgrade 06

 

  1. Click on “Start Update” to start the firmware update, and the following image will appear “Do not unplug the VCM II from the PC or remove power from the VCM II during the update process.”

Vcm Ii Firmware Upgrade Downgrade 07

 

  1. After clicking on “OK”, the following image will appear to start writing the new version of firmware.

Vcm Ii Firmware Upgrade Downgrade 08

 

  1. When the upgrade completed, the following prompt interface will appear, and the VCM II will automatically restart,wait until you hear the “beep”. Now exit VCM II Manger.

Vcm Ii Firmware Upgrade Downgrade 09

 

  1. Run the IDS. When the icon shown in the figure below appears, the VCM update is complete and it can be used normally.

Vcm Ii Firmware Upgrade Downgrade 10

Enjoy!