Product Description
OPS working on cars with optical fiber, both diagnose and programming for BMW cars. Works with models from E65 on. DIS version for hard disk fit all laptops is V57, SSS is V41. It support multi-language, and obd365 always provide you the best service.
OPS Diagnose and Coding Tool for BMW Fit All Computers
OPS works for BMW car model before 2009 year, it you want do BMW old and new car together, please choose
BMW ICOM or
BMW ICOM A2.
Top 3 Reasons to Get OPS:
1. Software Version: SSS V41, DIS V57
2. Hard disk is fit all laptops.
3. Support Multi languages:
SSS - German, French, Spanish, Italian, Netherland, Swedish, Japan, Chinese, Korean, Thai, Taiwan, Russian, Indonesian, Turkish, Greek, Portuguese;
DIS - English/ Chinese
What is the advantage of hard disk fit all computers?
The advantage is it do not have much demand on laptop,only require your laptop support USB 2.0. But this one software installation need pay a little bit attention.the installation maunal you can download from our website. The version for this hard disk is DIS V57 SSS V39.
Compared with T30 version hard disk,the hard disk fit IBM T30 speed may more fast and stable.We suggest this one to those who have IBM T30.
Item specification:
On vehicle models from the E65 on, BMW is for the first time using fibre-optic cables as standard for communication between control units.
The optical buses are notable for their high data transmission rate and they are not susceptible to electromagnetic interference. The optical buses in question are the MOST bus, primarily used for in-car entertainment electronics, and the byteflight bus, which serves predominantly safety-critical functions.
OPPS has been designed for encoding, individualising and programming ( CIP) via the Software Service Station (SSS) and envisaged for use as part of the BMW diagnostic system (DIS) from DISPlus and Group Tester One (GT1). It is intended for testing and programming tasks from the E65 series, taking the place of the diagnostic head.
OPS is intended for rapid programming of control units.
When operated at the SSS, no diagnostic or technical measuring pro-cedures are possible, as no measuring technology is incorporated; in this instance, OPPS / OPS is used predominantly for programming control units (flashing). Communication with the vehicle can be performed both via the MOST and via the OBD interface. The OBD interface is required for the power supply to the OPPS / OPS and has communication properties via which the vehicle can be identified and the data to be programmed can be determined. From CIP version 7.0, it is possible to delete fault code memories via OPPS / OPS.
OPS with DIS for diagnosis Supported Models:
Vehicle interface via OBD-II socket:
E87, E90, E91, E92, E60, E61, E63, E64, E65, E66, E70, E83, E85, E86, E38(OBD-II), E39(OBD-II ), E46(OBD-II ), E52, E53, R56, R50, R52, R53
OPS with SSS for programming Supported Models:
(1) Vehicle interface via OBD-II socket:
E87, E90, E91, E92, E60, E61, E63, E64, E65, E66, E70, E83, R56, R50, R52, R53
(2) MOST compatibility ( multichannel programming):
E87, E90, E91, E92, E60, E61, E63, E64, E65, E66, E70, R56, R50, R52, R53
Package including:
1. OPS multiplexer(Orange Head)
2. OBD-II diagnostic cable
3. LAN cable
4. OPS MOST cable
5. Hard disk
FAQ:
Q: How to update this product?
A: This product update is through hard disk.You can send the old hard disk back to us and we install the new software in the hard disk and send back to you.You only have to pay the shipping cost for this update.
Q: What is the difference between OPS and OPPS?
A: This two product almose the same function.Compared with OPS,the quality of OPPS better.
Q: Does this BMW OPS support an old models like E36,E34 and E39?
A: You can download the car model that BMW OPS support from our website.It can works on E36 E34 E39.
Q: How to use the MOST cable?
If you want to use the ops to diagnose, you need use the MOST cable. You need not connect MOST cable to car, but just use one interface plug into OPS head and another interface into the computer/PC COM port, in order to create a LAN Emulation.


We are here for you:Skype: OBDII365.comEmail: Sales@OBDII365.comWhatsapp : +86 18150118226
Tech Support
bmw-ops-gt1-dis-operation-manual.pdf
bmw-ops-model-series.pdf
ops-and-gt1.pdf
How To Run BMW OPS and BMW GT1 SSS System
Check “How to run BMW OPS and BMW GT1 SSS system” in the "Related Download Files".
When using BMW GT1,BMW OPS,BMW Mini OPS HDD with IBM T30, how to switch between DIS Diagnostic Device and SSS32 Diagnostic Device?
Reply: DIS Diagnostic Device and SSS V32 Diagnostic Device both run with DOS system.
1) To run DIS Diagnostic Device, it works automatically.
2) To run SSS V32 Diagnostic Device, see the follows:
A) Open IBM T30, then wait for a while, until IBM T30 screen shows “Boot” words: see the photo:
B) Press “space” key. Or any key of “up” “down” “left” “right” is ok!
C) Input “bootos”+ 'space” key+ “3”, then press “enter” key.

D) Then the Following Ccreen Appears.

E) Then the IBM T30 screen becomes black, then white, until the following screen appears. Now it is ready to run SSS32 Diagnostic Device

Attention: sometimes IBM T30 will restart, if it will, repeat the above-mentioned
1. Be sure to disable/uninstall anti-virus software
Please note,anti-virus software can flag up BMW OPS software as having a virus. This is a false positive and is due to the software containing the application file. So Before setup the device software, please disable/uninstall anti-virus software or install a more reliable free virus scanner! Our BMW OPS software is completely safe and virus free and all other virus scanners confirm this.
If the software data is destroyed or lost because you forget to disable/uninstall anti-virus software, please contact our customer service, we arrange to resend you CD or send you the software via internet.
2. Required windows operation system is windows XP
Be sure to setup and run the device software under windows XP. Otherwise the device software and program can be broken or it will fail to work.
SSS Program
A: Hello, I am trying to install sss progman v32 on a PC but I receive a hardware error shortly at the beginning of the installation. Can somebody point me in the right direction? I am just guessing that some configuration in the bios is not ok. Anyway, my PC in an Athlon XP 2400+ with s3 trio vid card. Everything else in onboard.
B: Necessary to crack HWVer.dll. Are you trying to install on IBM laptop or just a normal Desktop? Don’t forget to replace HWver.dll again in windows/system32 after installing winxp base.
A: With the replace of that file now it's working. I have never thought that this solution could work. Although, I had another problem but it's ok for now. I had to replace my hard drive because it was only 40G to a bigger one.
I am still receiving an error... When the installation is finished, and the PC has dopped the DVD from the drive the computer is not responding. I mean the mouse and the keyboard is working but the installation is stopped. See the picture below. Tell me what do you think. PS. I installed SSS a couple of days ago on another PC with no problems. This one is making me crazy.
A: *Did you change HWver after installing Base XP3.1?in windows\system32
*Are you sure HDD is 80GB or bigger?
*Are all drivers for hardware installed and recognized?
B: after the base installation with the help of a linux live CDI copied in c:/windows/system32 the Hwver file. After this the installation has began. My hard drive is 160GB. I don’t know nothing about the drivers, cause the installation is fully automatic (no VMware) Ps. I have 3 DVD-s: 1-base; 2-disk 2; 3-disk 3
How much memory do I need? I tried with 256MB, now I am triing with 1G.
A: Memory doesn’t matter.
You need to change the startup manager in registry.
You must use explorer so you can get in Device manager.
Do you have ERD commander?? With this tool you can edit the registry of windows XP 3.1 base.
B: Yes, I have Erd Commander. Can you please tell me step-by-step what should I do? most importantly in the registry.Thanks, Are there any specific configurations in the PC regarding the hard drive and the DVDROM? I have 1 idea cable, the DVDROM is the master and my hard drive is the slave. I have made some changes and after the base installation the system drops the first DVD and the system is restarting. After this I can do nothing because the system is not recognizing the first DVD.Can somebody point me in the right direction?
A: Use ERD commander to edit registry.
go to MICROSOFT / WINDOWS NT / CURRENT VERSION / WINLOGON
in LOCAL MACHINE
and change the SHELL value in "explorer.exe"
pls save or write down the old value!!!!!!!!!!!!
restart pc.
Now you will see normal windows GUI
log in as Administrator
pass: ++Xs4Progman
Disabable Progman AOS services
now you can enter device manager to install all hardware drivers.
after installing drivers enable Program AOS services and change registry value same as before to start programming installation.
B: Thanks man! Now it's working.